ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Condenser to Evaporator Line|Page 9959 > < Condenser to Evaporator Line
Page 2
background image

3. Remove the line clip at the evaporator connection.

4. Fit Spring Lock Coupling Disconnect Tool to the condenser lines so that the spring lock coupling tool can enter the cage opening to release the

A/C tube lock coupling spring.

5. Push the tool into the cage opening to release the female fitting from the A/C tube lock coupling spring.

6. Pull the spring lock coupling fittings apart.

Condenser to Evaporator Line|Page 9959 > < Condenser to Evaporator Line