Transmission Cooler: Service and Repair
Backflushing and Cleaning

1. Conduct backflushing with a Torque Converter/Oil Cooler Cleaner. Test your equipment to make sure that a vigorous fluid flow is present before

proceeding. Replace the system filter if flow is weak or contaminated.

2. To aid in attaching the cleaner to the transmission steel cooler lines connect two additional rubber hose, to the transmission end of the steel

transmission cooler lines.
1

Connect the cleaner tank pressure line to the steel transmission cooler return line (longest line).

2

Connect a tank return hose to the steel transmission cooler pressure line (shorter line). 

3

Place the outlet end of this hose in the solvent tank reservoir.

4

Turn on solvent pump and allow the solvent to circulate a minimum of 5 minutes (cycling switch on an d off will help dislodge contaminants in
cooler system).

4. Switch off the solvent pump and disconnect the solvent pressure hose from the transmission cooler return line.
5. Use compressed air to blow out the cooler(s) and lines (blow air into the transmission cooler return line) until all solvent is removed.
6. Remove the rubber return hose from the remaining steel cooler line.

Auxiliary|Page 4781 > < Auxiliary|Page 4779