ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Instruments - Speedo. Doesn't Return To Zero At A Stop|Page 3298 > < Electronic Throttle Control Module|Description and Operation|Page 3289
Page 1
background image

Engine Control Module: Customer Interest
Instruments - Speedo. Doesn't Return To Zero At A Stop

TSB 10-4-2

03/15/10

SPEEDOMETER - NOT RETURNING TO ZERO WHILE 
IN PARK AND ENGINE RUNNING

FORD:
2007-2008 Expedition

ISSUE
Some 2007-2008 Expedition vehicles may exhibit symptoms of speedometer fluctuation while the engine is running and transmission is in park position.

ACTION
Follow the Service Procedure steps to correct the condition.

SERVICE PROCEDURE

1. Install Integrated Diagnostic System (IDS)/Portable Diagnostic Software (PDS) or equivalent and start a session, identify (ID) vehicle.

2. Update the powertrain control module (PCM)/transmission control module (TCM) calibration using IDS release 65.06 and higher. This new

calibration is not included in the VCM 2010.1 DVD. Calibration files may also be obtained at the website.

NOTE

THE TCM CANNOT BE INDEPENDENTLY REPROGRAMMED, REPROGRAM USING THE PMI FUNCTION TO ENSURE THAT ENGINE
AND TRANSMISSION CALIBRATIONS ARE UPDATED TO THE LATEST LEVEL SIMULTANEOUSLY.

3. Verify that the 1CM Calibration shows 8L1P-7J104-AD (8L1P-7J104-BD for later production 2008 model year) part number after reprogramming is

complete.

a. Select the following from the IDS tool:

(1) Toolbox.

(2) Powertrain.

(3) 0DB Test Modes.

(4) Mode Level 9 Vehicle Information.

(5) TCM Cal Part Number.

NOTE

IT IS CRITICAL THAT TCM KEEP ALIVE MEMORY (KAM) BE CLEARED FOR PROCEDURE TO BE FULLY EFFECTIVE

4. Clear TCM KAM and adaptive tables.

a. Using IDS:

(1) Open Toolbox.

(2) Choose Powertrain.

(3) Choose Reset KAM.

(4) Choose TCM.

b. Using PDS:

(1) Choose all Tests and Calibrations.

(2) Scroll down the menu and choose reset TCM KAM

Instruments - Speedo. Doesn't Return To Zero At A Stop|Page 3298 > < Electronic Throttle Control Module|Description and Operation|Page 3289