ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Housing Assembly HVAC > < Hose/Line HVAC|Service and Repair
Page 2
background image

6. Remove the nut and disconnect the auxiliary A/C line fitting.

-

Discard the O-ring seal.

All vehicles

7. Remove the nut and disconnect the A/C fitting.

-

Discard the O-ring seal.

8. Loosen the bolt and remove the compressor manifold and tube assembly.

-

Discard the O-ring seals.

9. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

10. Evacuate, leak test and charge the refrigerant system.

Housing Assembly HVAC > < Hose/Line HVAC|Service and Repair