If a change of status occurs at one of these inputs while the GEM is in sleep mode, the GEM will activate. When the GEM activates, it performs an
internal self test, and begins normal operation. At this point, the GEM will have all of its functions operational.

The GEM will go into sleep mode immediately after both of the following conditions have been met:

^

Key in OFF position.

^

After 45 minutes with no change on any activation input.

The GEM control system has two modes of operation, the normal operating mode and tester dependent diagnostics mode.

The normal operation of the GEM can detect errors. An integral part of the normal GEM operation is the continuous diagnostic capability. Continuous
diagnostics detects errors and changes the GEM control strategy. There is no warning light for the GEM; therefore, a DTC concern will direct the
technician to the GEM. Examples of faults that may be detected during normal operation include:

^

GEM continuous self test (RAM, ROM, EEPROM, A/D checking).

^

Output driver monitoring (open circuit/short to GND, short to battery).

^

Illogical combinations of input signals.

NOTE:  The GEM can only detect open circuit/short to GND faults when the GEM is not energizing a load, and short to battery faults when the
GEM is attempting to energize a load.

Heated Backlite and Mirror Timer

When the rear window defrost switch is pressed, a 10-minute timer is started and the GEM energizes a relay that provides battery voltage to the heated
backlite (and the outside rear view mirrors if installed). The rear window defrost heats up to defog the rear window or melt accumulated snow or ice.

The GEM de-energizes the relay when either 10 minutes have elapsed, the rear window defrost switch is pressed again, or the ignition switch is turned to
OFF or ACCY. The 10-minute timer is temporarily halted if the ignition switch is turned to START, and resumes after the ignition switch is returned to
RUN.

Windshield Wiper Control and Interval Timer

There are five modes of operation for the front wiper: MIST, INTERVAL (speed-dependent), LOW, HIGH, and WASH.

These modes are only active with the ignition switch in the RUN or ACCY position.

Front Windshield Wiper Control (with Speed Dependent Interval Wiper) 

The GEM responds to the windshield wiper control commands by interpreting inputs from the steering column seven-position delay/wash and
four-position mode select switches. Except when the seven position switch is in interval 1, the speed dependent wipers will compensate for the
extra moisture that accumulates on the windshield at higher speeds. At higher speeds, the speed dependent feature shortens the delay between
wipes when using the variable interval wipers. Delays will automatically adjust at speeds between 16 and 105 kph (10 and 65 mph).

The GEM relay drivers control three external relays: wiper high/low speed relay, dynamic brake-run relay, and the washer pump relay. When
the washer switch is activated longer than 300 ms, the wash and wiper (low speed) functions are provided until the switch is released. The
release of the switch will be followed by three low speed wipes. If the switch is pressed between 100 ms and 300 ms (with the mode in the
OFF position), the wiper system will provide one wipe at low speed with no wash.

Modes: OFF, Interval, LOW, HIGH, and WASH.

INTERVAL 

For standard interval, the time between low-speed wipes will range from 1.5 to 20 seconds. These delays will shorten as vehicle speed
increases up to 105 kph (65 mph). This feature is not active when the seven position switch is in interval 1 position.

HI 

This is the fastest wiper speed with no dwell. It is selected when the multi-function switch is in the HI speed position. If the wash button is
pressed for 0.3 to 10 seconds, the washer pump will energize until the wash button is released.

LO 

This is the slowest wiper speed with no dwell. It is selected when the multi-function switch is in the LO speed position. If the wash button
is pressed for 0.3 to 10 seconds, the washer pump will energize until the wash button is released.

WASH 

If the wash button is pressed for 0.3 to 10 seconds, the washer pump will energize until the wash button is released.

Rear Interval Wiper Control

The GEM responds to the rear wiper control commands by interpreting inputs from the rear wiper mode wash switch. There are two modes of operation
for the rear wiper: INTERVAL and LOW. In the low speed setting, there is no dwell time. There will be two interval wiper settings to provide the
following rear wiper dwell times.

^

Setting 1 is 12 Seconds Dwell.

With Power Windows|Page 10630 > < With Power Windows