ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Lamp Control Module > < Interior Lighting Relay|Locations|Page 12791
Page 1
background image

Interior Lighting Relay: Testing and Inspection

Testing an ISO relay can be accomplished through the use of three No.10 (or larger gauge) jumper wires and 73 Digital Multimeter. Remove the relay to
be tested from the power distribution box, fuse junction panel or individual connector.

Micro ISO Relay

Use 73 Digital Multimeter to check for continuity between terminal 2 and all other terminals. If resistance is 5 ohms or less between terminal 2 and any
other terminal, replace the relay. If resistance is greater than 5 ohms, continue the test. Use two jumper wires to connect relay terminals 1 and 3 directly
to the positive battery terminal. Set 73 Digital Multimeter in volts position and check for voltage at terminal 4. If battery voltage is not indicated, replace
the relay. If battery voltage is indicated, connect the third jumper wire to terminal 2, and ground the jumper wire to chassis ground. Check for voltage at
terminal 5. If battery voltage is not indicated, replace the relay.

Lamp Control Module > < Interior Lighting Relay|Locations|Page 12791