ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4108 > < Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4106
Page 44
background image

2. If the concern remains after inspection, connect the New Generation STAR (NGS) Tester to the Data Link Connector (DLC) located beneath the

instrument panel and select the vehicle to be tested from NGS Tester menu. If NGS Tester does not communicate with the vehicle:
^

check that the program card is correctly installed.

^

check the connections to the vehicle.

^

check the ignition switch is in RUN position. If the NGS Tester still will not communicate with the vehicle, refer to Information Bus.

3. Refer to the Symptom Chart.  See: Module Configuration/Symptom Chart

Principles of Operation

NOTE:

^

Newly released modules will require configuration after being installed on the vehicle. All configurable modules will be packaged in a kit which
contains a warning label and a multi-language sheet re-emphasizing the requirements to configure replacement modules.

^

The powertrain control module (PCM) has to be flash programmed using a flash cable.

Customer Driven Preferences
There are customer preference items that can or need to be configured on this vehicle. These are items that the customer may or may not want to
have enabled. Typically, customer preference items can be toggled on or off by the use of a Ford compatible scan tool. You may need to ask the
customer which preferences they had enabled prior to installation of the new module.

To carry out the customer configuration process, use a Ford Service Function (FSF) card and the NGS Tester. Refer to the Customer Preference
Index for modules on the vehicle that have customer preference items.  See: Module Configuration/Customer Preference Index
Configure the items as needed with a Ford compatible scan tool.

Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4108 > < Multiplex Communication Network <--> [Information Bus]|Flow of Diagnosis|Page 4106