ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor To Condenser Discharge Line|Page 6047 > < Compressor To Condenser Discharge Line|Page 6045
Page 2
background image

6. Remove the 2 rear auxiliary evaporator line front fitting nuts and disconnect the fittings.

-

Discard the O-ring seals.

-

To install, tighten to 8 Nm (71 lb-in).

7. Remove the 2 rear auxiliary evaporator line rear fitting nuts and disconnect the fittings.

-

Discard the O-ring seals.

-

To install, tighten to 8 Nm (71 lb-in).

8. Remove the auxiliary line bracket nut.

-

To install, tighten to 6 Nm (53 lb-in).

9. Remove the 2 auxiliary line brackets.

10. Remove the rear auxiliary evaporator outlet line.

11. Remove the rear auxiliary evaporator inlet line.

-

Discard the Thermostatic Expansion Valve (TXV) filter.

12. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Install a new TXV filter.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

13. Evacuate, leak test and charge the refrigerant system.

Compressor To Condenser Discharge Line|Page 6047 > < Compressor To Condenser Discharge Line|Page 6045