Positive Crankcase Ventilation Valve: Service and Repair

Positive Crankcase Ventilation (PCV) Valve - 4.0L SOHC

Removal and Installation

1. Disconnect the PCV valve electrical connector.

2. Disconnect the PCV valve hose.

3. NOTE: If the PCV valve is removed from the valve cover, a new PCV valve must be installed.

Rotate the PCV valve counterclockwise and remove it from the valve cover.

4. To install, reverse the removal procedure.