Page 17
background image

G5

Normal Operation

The instrument cluster communicates with the scan tool through the high speed controller area network (HS-CAN). Circuits VDB04 (WH/BU)
(HS-CAN +) and VDB05 (WH) (HS-CAN -) provide the HS-CAN network connection to the instrument cluster and circuits VDB06 (GY/OG)
(MS-CAN +) and VDB07 (VT/OG) (MS-CAN -) provide the MS-CAN network connection to the instrument cluster. The instrument cluster shares
the HS-CAN network with the powertrain control module (PCM), the transmission control module (TCM) (if equipped), the anti-lock brake system
(ABS) module, the restraint control module (RCM), the four wheel drive (4WD) control module (if equipped) and the occupant classification sensor
module. The instrument cluster shares the MS-CAN network with the smart junction box (SJB), the electronic automatic temperature control (EATC)
module (if equipped), the audio unit, the satellite radio receiver (if equipped), the driver seat module (DSM) (if equipped), the parking aid module (if
equipped), the power running board module (if equipped) and the digital versatile disc (DVD) player (if equipped). Voltage for the instrument cluster
is provided by circuits CDC34 (WH/OG) and SBP24 (VT/RD). Circuit GD145 (BK/BU) provides ground.

Possible Causes

-

Fuse

-

Circuit CDC34 (WH/OG) open

-

Circuit GD145 (BK/BU) open

-

Circuit SBP24 (VT/RD) open

-

Circuit VDB04 (WH/BU) open (HS-CAN +)

-

Circuit VDB05 (WH) open (HS-CAN -)

-

Instrument cluster

Test H: The Smart Junction Box (SJB) Does Not Respond to the Scan Tool

PINPOINT TEST H: THE SMART JUNCTION BOX (SJB) DOES NOT RESPOND TO THE SCAN TOOL

H1