4

Remove the driver air bag module.

5. Attach the restraint system diagnostic tool to the clockspring electrical connector at the top of the steering column.

6. Push in on the glove compartment sides, releasing the stops and lowering it out of the way.

7. Through the glove compartment opening, release the tab and disconnect the passenger air bag module electrical connector.

8. Attach the restraint system diagnostic tool to the vehicle harness side of the passenger air bag electrical connector.

Vehicles without side air curtains

9. If the side air curtain bridge resistor is removed, an open circuit fault will be generated by the Restraints Control Module (RCM).

If a restraint system diagnostic tool is installed at the side air curtain electrical connector, a low resistance fault will be generated by the RCM.