ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Disassembly and Assembly|Page 6868 > < Disassembly and Assembly|Page 6866
Page 2
background image

5. Remove the converter drain plug and discard.

6. NOTE:  Clean the area around connector to prevent contamination of the solenoid body connector.

Disconnect the solenoid body harness connector.

7. NOTE:  The transmission fluid pan gasket is reusable, clean and inspect for damage. If not damaged, the gasket should be reused. 

Remove the 16 transmission fluid pan screws, fluid pan, and gasket.

8. Remove the transmission fluid filter.

9. Remove the solenoid body.

Disassembly and Assembly|Page 6868 > < Disassembly and Assembly|Page 6866