ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Blower Motor - Burning Odor/Smoke/Rustling Noise|Page 9020 > < EATC - No Setpoint/Blower Stays on HIGH|Page 9015
Page 1
background image

Blower Motor: Customer Interest
Blower Motor - Burning Odor/Smoke/Rustling Noise

Article No.
99-20-6

10/04/99

^

AIR CONDITIONING - BURNING ODOR OR SMOKE 
WHILE BLOWER MOTOR IS ON

^

NOISE - "RUSTLING" HEARD ALONG WITH AN 
ODOR WHILE BLOWER MOTOR IS ON

FORD:
1991-1999 EXPLORER

MERCURY:
1997-1999 MOUNTAINEER

This TSB article is being republished in its entirety to change the Causal Part number.

ISSUE
A burning odor or smoke, and/or "rustling" noise may occur when the blower motor is running if leaves or foreign material enter the blower case. Noise
complaints may result from debris coming in contact with the blower fan. In some cases, the debris may also come in contact with the blower motor
resistor which may be hot enough to cause a burning odor or smoke.

ACTION
Clean the debris out of the blower case and install foam grommets around the wiper pivots to seal out further debris from entering the system. Refer to
the following Service Procedure for details.

SERVICE PROCEDURE

ALL MODEL YEARS - CLEAN DEBRIS FROM THE HEATER CASE

1.

Remove blower motor (refer to the appropriate Service or Workshop Manual for procedure).

2.

Remove blower motor resistor.

NOTE

BE CAREFUL NOT TO DAMAGE OR BEND RESISTOR COILS WHICH COULD RESULT IN AN ELECTRICAL SHORT.

3.

Clean the blower motor, motor cooling tube, blower housing, resistor, and inlet duct of all debris.

4.

Reinstall resistor.

5.

Reinstall blower motor.

1991-1994 MODELS YEARS - INSTALL FOAM GROMMETS AROUND WIPER PIVOTS

Blower Motor - Burning Odor/Smoke/Rustling Noise|Page 9020 > < EATC - No Setpoint/Blower Stays on HIGH|Page 9015