ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporative System Service Port > < Evaporative Emission Control Canister|Specifications|Page 4670
Page 2
background image

2

Remove the EVAP canister with bracket assembly.

7. Remove the canister vent solenoid and the evaporative emission tube.

1

Remove the canister vent solenoid.

2

Remove the evaporative emission canister purge sleeve.

3

Remove the evaporative emission tube.

8. Remove the evaporative emission canister from the evaporative emission canister bracket.

INSTALLATION

1. To install, reverse removal procedure.

NOTE:  Lubricate all O-rings with Merpol (R) ESE-M99B144-B or equivalent before installation.

2. Leak test the evaporative emissions system.  See: Testing and Inspection/Component Tests and General Diagnostics/Evaporative Emission

Canister Assembly Leak Test

3. Perform the Evaporative Emission Running Loss Monitor Repair Verification Drive Cycle. 

Evaporative System Service Port > < Evaporative Emission Control Canister|Specifications|Page 4670