Removal

 

CAUTION: The camshaft procedure must be followed exactly or damage to the valves and pistons will result.

1. Position the crankshaft damper spoke at the 12 o'clock position and the timing mark indentation at the 1 o'clock position.

2. Remove the LH valve cover.

3. CAUTION: Damage to the camshaft phaser and sprocket assembly will occur if mishandled or used as a lifting or leveraging device.

Loosen and back off the LH camshaft phaser and sprocket bolt one full turn.

4. Disconnect the LH camshaft position (CMP) sensor electrical connector.

5. Remove the LH CMP sensor and the bolt.