ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compression Check > < Variable Camshaft Timing (VCT) Valve 1|Page 2973
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair

VARIABLE CAMSHAFT TIMING (VCT) OIL CONTROL SOLENOID

Removal and Installation

1. Disconnect the battery ground cable.
2. Disconnect the variable camshaft timing (VCT) oil control solenoid electrical connector.
3. Remove the grommet.
4. Remove the bolt and the VCT oil control solenoid.

-

To install, tighten to 5 Nm (44 lb-in).

5. To install, reverse the removal procedure

Compression Check > < Variable Camshaft Timing (VCT) Valve 1|Page 2973