Repair is made by installing a new part only. If the new part does not correct the condition, install the original part and carry out the diagnostic
procedure again.

1. Depower the system.
2. Remove the floor console.

3. Disconnect the large RCM electrical connector.

1

Pinch the thumb tab and pivot the large RCM electrical connector position assurance lever all the way back until it stops.

2

Pull out and disconnect the large RCM electrical connector.

4. Press to release the locking tab and disconnect the small RCM electrical connector.
5. Remove the 3 RCM nuts.
6. Remove the RCM.

Installation

1. Install the RCM.
2. Install the 3 RCM nuts.

-

Tighten to 12 Nm (9 lb-ft).

3. Connect the small RCM electrical connector.

4. NOTE:  The RCM has been removed for clarity.

On the large RCM electrical connector, place the connector position assurance lever in the full release position.