ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2930 > < Initial Inspection and Diagnostic Overview|Page 2928
Page 22
background image

-

Measure the resistance between the HVAC module C228a-2, circuit GD145 (BK/BU) and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to I3.

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
I3 CHECK THE MS-CAN CIRCUITS BETWEEN THE HVAC MODULE AND THE DLC FOR AN OPEN

-

Measure the resistance between the HVAC module C228a-11, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06
(GY/OG), harness side.

-

Measure the resistance between the HVAC module C228a-1, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07
(VT/OG), harness side.

-

Are the resistances less than 5 ohms?

Yes

CONNECT the negative battery cable. GO to I4.

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
I4 CHECK FOR CORRECT HVAC MODULE OPERATION

-

Disconnect all the HVAC module connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the HVAC module connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

Initial Inspection and Diagnostic Overview|Page 2930 > < Initial Inspection and Diagnostic Overview|Page 2928