10. Position forward the air deflector.

11. Remove the nut and position aside the suction accumulator.

12. Remove the nut and the condenser to evaporator line.

-

Discard the O-ring seals.

INSTALLATION

1. To install, reverse the removal procedure.

-

If a new condenser to evaporator line is to be installed, lubricate the refrigerant system with the correct amount of clean PAG oil or equivalent.

-

Install new O-ring seals lubricated in clean PAG oil or equivalent.

2. Evacuate, leak test, and charge the refrigerant system.

With Auxiliary Climate Control

REMOVAL

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Remove the air cleaner housing and the air cleaner outlet tube.