ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Housing Assembly HVAC > < Auxiliary Climate Control|Page 11737
Page 7
background image

13. Remove the nut and the condenser to evaporator line.

-

Discard the O-ring seals.

INSTALLATION

1. To install, reverse the removal procedure.

-

If a new condenser to evaporator line is to be installed, lubricate the refrigerant system with the correct amount of clean PAG oil or equivalent.

-

Install new O-ring seals lubricated in clean PAG oil or equivalent.

2. Evacuate, leak test, and charge the refrigerant system.

Housing Assembly HVAC > < Auxiliary Climate Control|Page 11737