ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Auxiliary Climate Control|Page 2442 > < Auxiliary Climate Control|Page 2440
Page 2
background image

INSTALLATION

1. To install, reverse the removal procedure.
2. Lubricate the refrigerant system with the correct amount of clean PAG oil.
3. Evacuate, leak test and charge the refrigerant system.

Condenser to Evaporator Line

CONDENSER TO EVAPORATOR LINE

REMOVAL

NOTE:

-

Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

-

New O-ring seals, lubricated in clean PAG oil must be installed before reconnecting any A/C fitting which has been disconnected.

1. Remove the air cleaner and air cleaner outlet tube.
2. Remove the suction accumulator.
3. Recover the refrigerant.

4. Remove the components in the order indicated in the illustration and table.

INSTALLATION

1. To install, reverse the removal procedure.
2. Lubricate the refrigerant system with the correct amount of clean PAG oil.

Auxiliary Climate Control|Page 2442 > < Auxiliary Climate Control|Page 2440