ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4882 > < Diagram Information and Instructions|Page 4880
Page 1
background image

Shift Solenoid: Description and Operation

Shift Solenoids  (SSA, SSB, SSC, SSD) 

Four On/Off shift solenoids allow the powertrain control module (PCM) to control shift scheduling. 

The solenoids are three-way, normally open style. 
The shift solenoids SSA, SSB, SSC, and SSD provide gear selection of first through fifth and reverse gears by directing PC pressures to the appropriate
elements. 
Coast braking and manual gears are also controlled by the shift solenoids.

Diagram Information and Instructions|Page 4882 > < Diagram Information and Instructions|Page 4880