1. Make sure the connector position assurance lever is in the full release position before attempting to connect the connector.

2. CAUTION:  Putting the large RCM electrical connector into the RCM on an angle can cause bad electrical connections and damage

components.

NOTE:  The RCM has been removed for clarity.

Position the large RCM electrical connector into the RCM.

-

CAUTION:  Do not push the connector on to where the lever pivots and seats itself. Light pressure is needed to get the connector into
position on the RCM before using the lever to fully seat the connector.

With the large RCM electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and a slight
resistance is felt.