ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 6719 > < Initial Inspection and Diagnostic Overview|Page 6717
Page 24
background image

-

Is the voltage greater than 10 volts?

Yes

GO to AD6.

No

REPAIR circuit GD138 (BK/WH) for an open. TEST the system for normal operation.

-------------------------------------------------
AD6 CHECK THE TBC MODULE OUTPUT CIRCUIT FOR A SHORT TO GROUND

-

Measure the resistance between the TBC module C239-3, circuit CAT19 (BU), harness side and ground.

-

Is the resistance greater than 10,000 ohms?

Yes

GO to AD7.

No

REPAIR circuit CAT19 (BU) for a short to ground. TEST the system for normal operation.

-------------------------------------------------
AD7 CHECK THE TBC MODULE OUTPUT CIRCUIT FOR AN OPEN

-

Measure the resistance between the TBC module C239-3, circuit CAT19 (BU), harness side and the trailer tow C473-3, circuit CAT19 (BU),
harness side.

-

Is the resistance less than 5 ohms?

Yes

Initial Inspection and Diagnostic Overview|Page 6719 > < Initial Inspection and Diagnostic Overview|Page 6717