Removal

1. Remove the LH ignition coils. For additional information, refer to Ignition System.

2. Remove the bolt and position the oil level indicator and tube aside.

3. Disconnect the Evaporative Emission (EVAP) tube from the intake manifold.

4. Disconnect the PCV hose from the valve cover.

5. Remove the nut and position the cooling fan wiring harness bracket aside.

6. Disconnect the 2 pin-type retainers from the valve cover.

7. Disconnect the Variable Camshaft Timing (VCT) solenoid electrical connector.

8. Detach the wiring harness retainers from the valve cover studs.

9. Disconnect the EVAP canister purge valve electrical connector.

10. Disconnect the EVAP canister-to-EVAP canister purge valve EVAP hose from the EVAP canister purge valve.

11. Loosen the 10 bolts and remove the LH valve cover and gasket.

-

Discard the gasket.

Installation

1. NOTICE: Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These tools

cause scratches and gouges which make leak paths. Use a plastic scraping tool to remove all traces of old sealant.

Clean the gasket mating surfaces.

-

Clean the valve cover mating surface of the cylinder head with silicone gasket remover and metal surface prep. Follow the directions on the
packaging.

-

Clean the valve cover gasket groove in the valve cover with soap and water or a suitable solvent.

2. Install a new gasket on the LH valve cover.

3. NOTE: If the valve cover is not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with metal surface cleaner.

Failure to follow this procedure may cause future oil leakage.

Apply a bead of silicone gasket and sealant in 2 places where the engine front cover meets the cylinder head.