No

VERIFY the Smart Junction Box (SJB) fuse 1 (20A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams to identify the
possible causes of the circuit short. CLEAR the DTCs. REPEAT the network test with the scan tool.  See: Diagrams/Electrical Diagrams/Diagrams By
Number

-------------------------------------------------
M2 CHECK THE DSM GROUND CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the DSM C341c-13, circuit GD143 (BK/VT), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to M3.

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
M3 CHECK THE MS-CAN CIRCUITS BETWEEN THE DLC AND THE DSM FOR AN OPEN

-

Measure the resistance between the DSM C341c-11, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06 (GY/OG),
harness side.

-

Measure the resistance between the DSM C341c-12, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG),
harness side.

-

Are the resistances less than 5 ohms?

Yes

CONNECT the negative battery cable. GO to M4.

No

Initial Inspection and Diagnostic Overview|Page 2820 > < Initial Inspection and Diagnostic Overview|Page 2818