ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2821 > < Initial Inspection and Diagnostic Overview|Page 2819
Page 32
background image

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
M4 CHECK FOR CORRECT DSM OPERATION

-

Disconnect all the DSM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the DSM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new DSM. REFER to Body Control Systems. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test N: The Power Running Board Module Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test N: The Power Running Board Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 109, Power Liftgate/Running Boards for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Normal Operation

The Power Running Board (PRB) module communicates with the scan tool through the Medium Speed Controller Area Network (MS-CAN).

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

PRB module

PINPOINT TEST N: THE PRB MODULE DOES NOT RESPOND TO THE SCAN TOOL

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE:  Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
N1 CHECK THE PRB MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: PRB Module C4322b.

-

Ignition ON.

-

Measure the voltage between the PRB module C4322b-1, circuit SBB19 (BU/RD), harness side and ground.

Initial Inspection and Diagnostic Overview|Page 2821 > < Initial Inspection and Diagnostic Overview|Page 2819