Auxiliary Step / Running Board > < Initial Inspection and Diagnostic Overview|Page 6980
Page 12
background image

No

GO to E4.

-------------------------------------------------
E4 RECHECK THE SJB DTCs

NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during Programmable Module
Installation (PMI) or the PMI may not have been carried out.

-

Clear the DTCs. Repeat the SJB self-test.

-

Is DTC U0164 still present?

Yes

INSTALL a new HVAC module. TEST the system for normal operation. REPEAT the SJB self-test.

If DTC U0164 is still present, INSTALL a new SJB. REFER to Smart Junction Box (SJB)  See: Power and Ground Distribution/Power Distribution
Module/Service and Repair.

No

The system is operating correctly at this time. The DTC may have been set due to high network traffic or intermittent fault condition.

-------------------------------------------------