5. Disconnect the suction accumulator/drier refrigerant lines.

CAUTION:  Use a back-up wrench to prevent damage to the tubes.

6. Remove the two screws and the suction accumulator/drier.

INSTALLATION

1. To install, reverse the removal procedure.

-

If a new suction accumulator/drier is to be installed, transfer the A/C cycling switch to the new suction accumulator/drier.

-

If a new suction accumulator/drier is to be installed, refer to refrigerant oil addition.

2. Evacuate, leak test, and charge the A/C system.