ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C - Front Blower Motor Whistling Noise|Page 7311 > < Ambient Temperature Sensor / Switch HVAC|Locations|Page 7302
Page 1
background image

Blower Motor: Customer Interest
A/C - Front Blower Motor Whistling Noise

TSB 07-12-6

06/25/07

FRONT BLOWER MOTOR WHISTLE NOISE - 
VEHICLES BUILT ON OR BEFORE 06/7/2007

FORD:
2006-2007 Explorer
2007 Explorer Sport Trac

MERCURY:
2006-2007 Mountaineer

ISSUE
Some 2006-2007 Explorer, Mountaineer and 2007 Sport Trac vehicles built on or before 6/7/2007 may exhibit a whistling noise from the instrument
panel coming from the front blower motor. Typically, the noise will occur when the blower motor is set to high speed, the air recirculation is deactivated
(fresh air mode) and when the climate control temperature is set to cold. The noise is due to an air gap in the blower motor housing at the electrical
connector.

ACTION
Follow the Service Procedure steps to correct the condition.

SERVICE PROCEDURE

To service, first verify if the noise is coming from this location. If the noise is coming from this location, seal the air gap. Refer to the following Concern
Verification method and Repair Procedure.

Concern Verification

1.

Locate the blower motor behind the dash panel on the right hand side.

2.

With the front blower motor running, place an object (such as a shop-towel) on top of the area behind the motor connector. There should be a
change in the noise frequency, or the noise may completely stop, but will return after clearing the area behind the electrical connector.

Repair Procedure

NOTE

IT IS NOT NECESSARY TO REMOVE THE MOTOR FROM THE INSTRUMENT PANEL TO PERFORM THIS PROCEDURE.

1.

Lower the glove box compartment.

2.

Disconnect the motor's electrical connector.

3.

Apply Motorcraft® Clear Silicone Rubber (TA-32) using a fine pointed nozzle in the area behind the electrical connector (Figure 1).

4.

Reconnect the electrical connector.