ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Extension Housing Seal, A/T|Page 6006 > < Extension Housing Seal, A/T|Page 6004
Page 4
background image

4. Align flats of the manual valve inner lever with flats on the manual control lever shaft. Install the manual valve inner lever and parking lever

actuating rod onto the manual control lever shaft.

5. CAUTION:  Do not bend the manual valve inner lever pin.

Install the manual valve inner lever nut.

6. CAUTION:  Park pawl actuating rod must be correctly installed into parking pawl and guide cup located in extension housing. Verify park

linkage function.

Verify that the output shaft is locked in the PARK position.

7. Install the manual valve detent spring.
8. Install the transmission fluid pan with new pan gasket.

9. If equipped, position the servo heat shield over the servos and clip it to the pan rail.

10. Install the digital Transmission Range (TR) sensor.
11. Lower the vehicle.

Extension Housing Seal, A/T|Page 6006 > < Extension Housing Seal, A/T|Page 6004