ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Compressor to Condenser Discharge Line|Page 7543 > < Compressor to Condenser Discharge Line|Page 7541
Page 2
background image

Part 2

Removal and Installation

1. Recover the refrigerant.
2. Disconnect the front auxiliary evaporator inlet line front fitting.

-

Discard the O-ring seals.

3. Remove the RH running board.
4. Disconnect the front auxiliary evaporator outlet line front fitting.
5. Remove the RH rear wheel.
6. Remove the front auxiliary evaporator line fitting nuts and disconnect the fittings.

-

Discard the O-ring seals.

-

To install, tighten to 8 Nm (71 lb-in).

7. Remove the 3 auxiliary line bracket nuts.

-

To install, tighten to 6 Nm (53 lb-in).

8. Remove the 3 auxiliary line bracket bolts.

-

To install, tighten to 6 Nm (53 lb-in).

9. Remove the 6 auxiliary line brackets.

10. Remove the front auxiliary evaporator outlet and inlet lines.
11. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

12. Evacuate, leak test and charge the refrigerant system.

Compressor to Condenser Discharge Line|Page 7543 > < Compressor to Condenser Discharge Line|Page 7541