2. Install the 3 RCM nuts.

-

Tighten to 12 Nm (9 lb-ft).

3. Connect the small RCM electrical connector.

4. NOTE:  The RCM has been removed for clarity.

On the large RCM electrical connector, place the connector position assurance lever in the full release position.

5. CAUTION:  Putting the large RCM electrical connector into the RCM on an angle can cause bad electrical connections and damage

components.

Position the large RCM electrical connector into the RCM.

6. Connect the large RCM connector.