ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Ignition System - Spark Plug Removal Instructions|Page 2028 > < Ignition System - Spark Plug Removal Instructions|Page 2026
Page 6
background image

drive.

CAUTION

DO NOT ATTEMPT TO REMOVE THE GROUND ELECTRODE SHIELD WITH THE TAP AND WRENCH. THE TAP MAY BREAK IF
THIS IS ATTEMPTED.

4.

Thread Rotunda special service tool 303-1203 into the ground electrode shield. (Figure 9)

a.

Install the stepped end of the tool pilot bushing into the spark plug well ensuring it bottoms out.

b.

Screw the center shank into the ground electrode shield. Do not over tighten the shank, to prevent thread stripping.

c.

Install the nylon washer and jack nut until finger tight.

d.

Turn the jack nut until the ground electrode is freed from the cavity and withdraw the tool assembly.

NOTE

NEW PLUGS SHOULD BE INSTALLED USING A FILM COATING OF MOTORCRAFT® HIGH TEMPERATURE NICKEL ANTI-SEIZE
LUBRICANT ON THE GROUND ELECTRODE SHIELD. DO NOT COAT THE ELECTRODE STRAP.

Mode 2 Procedure:

1.

Add an additional 1/2 teaspoon Motorcraft® Carburetor Tune-Up Cleaner fluid into spark plug well and allow 15 minutes of soak time.

2.

Using long-reach nose pliers grasp and remove the porcelain with an up and down motion taking care not to fracture the porcelain.

3.

Refer to Mode 1 Procedure to remove the remaining ground electrode shield from the cylinder head.

Mode 3 Procedure:

CAUTION

DO NOT DRIVE PORCELAIN DOWN INTO THE GROUND SHIELD WITH A PUNCH AS FRAGMENTS MAY ENTER THE
COMBUSTION CHAMBER.

Ignition System - Spark Plug Removal Instructions|Page 2028 > < Ignition System - Spark Plug Removal Instructions|Page 2026