6. Disconnect the suction accumulator inlet fitting.

-

Discard the O-ring seals.

7. Remove the 2 suction accumulator bracket nuts.

-

To install, tighten to 9 Nm (80 lb-in).

8. Remove the suction accumulator.
9. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

10. Evacuate, leak test and charge the refrigerant system.