ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Extension Housing Gasket|Page 4193 > < Extension Housing Gasket|Page 4191
Page 5
background image

2. Install the parking lever actuating rod.

1

Install the parking lever actuating rod.

2

Install the manual valve detent lever.

3. Install the manual control lever shaft.

1

Install the manual control lever shaft.

2

Install the inner manual control lever shaft nut.
^

Tighten to 31 Nm (23 ft. lbs.).

3

Install the manual valve control lever shaft retaining pin.

4. Install the manual valve detent lever spring and bolt.

^

Tighten to 10 Nm (89 inch lbs.).

5. Install the digital TR sensor and loosely install the bolts.

Extension Housing Gasket|Page 4193 > < Extension Housing Gasket|Page 4191