background image

5. Disconnect the quick connect coupling.

-

Push the quick connect coupling toward the tube to release pressure.

-

Press the tab corners to release the quick connect coupling.

-

Disconnect the quick connect coupling.

Connect - Type I

1. Inspect the quick connect coupling and the tube for damage. Remove any dirt or obstructions.

2. NOTE:

-

Make sure the fuel tube clicks into place when installing the tube. To make sure that the fuel tube is fully seated, pull on the tube.

-

Apply clean engine oil to the end of the tube or quick connect coupling before connecting.

Connect the tube into the quick connect coupling.

3. Press the locking tab down into the locked position.

Disconnect - Type II

WARNING:

-

When working on or near the evaporative emission (EVAP) system, disconnect the battery ground cable from the battery. The EVAP
system contains fuel vapor and condensed fuel vapor, so an electrical spark may cause a fire or explosion. Failure to follow this
instruction may result in serious personal injury.

-

Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component. Highly
flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.

-

Before working on or disconnecting any of the fuel tubes or fuel system components, relieve the fuel system pressure to prevent accidental
spraying of fuel. Fuel in the fuel system remains under high pressure, even when the engine is not running. Failure to follow this
instruction may result in serious personal injury.