The Central Timing Module (CTM) illuminates the interior courtesy lamps when any door is ajar. The Generic Electronic Module (GEM) has this
functionality plus it provides illuminated entry when the handle is lifted. All interior courtesy lamps are turned off when any of the following occur:

-

Twenty-five seconds have elapsed since the illuminated entry feature was activated.

-

The ignition switch is turned to RUN.

-

Vehicle speed is over 15 mph (a new ajar signal will turn on courtesy lamps only if the vehicle speed is less than 10 mph - GEM only).

-

A power door lock command is received from the remote entry key fob (GEM only).

Delayed Accessory (GEM only)

The delayed accessory feature provides power to the power windows for ten minutes after the ignition switch is moved from the RUN to the OFF
position. If during this ten-minute period either door is opened, the delayed accessory relay will be de-energized.

One-Touch Window (GEM only)

The power switch for the driver window control has two detents for the down window control. With the ignition switch in RUN or ACC, pressing the
first detent (normal mode) allows manual down window control; pressing harder to the second detent (auto) will cause the driver window to
automatically move to the full down position. Pressing either the up or down window switch will cancel an auto mode operation in progress.

Transfer Case (4-Wheel Drive - GEM Only)

Two types of 4-wheel drive systems are offered: the Mechanical Shift-On-the-Fly (MSOF) and the Electronic Shift-On-the-Fly (ESOF). 

RAP-Controlled Functions

The Remote Anti-theft Personality (RAP) module controls the door locks through three external relays located under the instrument panel relay cover:

-

Driver unlock relay.

-

All unlock relay.

-

All lock relay.

The RAP module receives input from the following components for electronic door lock system operation:

-

Keyless entry remote transmitters.

-

Door ajar output from the GEM.

-

Door unlock switches (LH/RH).

-

Brake ON/OFF switch.

-

Transmission Range (TR) sensor.

-

Remote entry antenna.