Accumulator HVAC: Service and Repair

REMOVAL

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.

1. Disconnect the battery ground cable.
2. Remove the junction block splash shield.

3. Remove the two cable ends from the starter relay.

4. Remove the two bolts and reposition the junction block bracket.
5. Recover the refrigerant.

6. Disconnect the A/C cycling switch electrical connector.

Accumulator HVAC|Description and Operation|Page 7332 > < Accumulator HVAC|Description and Operation