ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Fluorescent Dye Leak Detection|Page 7641 > < Fluorescent Dye Leak Detection|Page 7639
Page 3
background image

^

Before using the R-134a fluorescent dye injector for the first time, refer to the equipment manufacturers instructions on evacuation of
non-condensable gasses from the hoses.

^

Refrigerant system pressure should be between 413-551 kPa (60-80 psi) at 24°C.

1. Verify that the valves on the special tool are closed.

2. Fill the special tool reservoir with 7 ml (0.25 oz) of fluorescent dye.
3. Install the special tool between the high-pressure and low-pressure service gauge port valves.
4. Start the engine.

CAUTION:  Make sure all tools and hoses are dear of the engine cooling fan and drive belt before starting the engine.

5. Open the high-pressure service valve.

6. Open the special tool valves and inject the fluorescent dye into the refrigerant system.

Fluorescent Dye Leak Detection|Page 7641 > < Fluorescent Dye Leak Detection|Page 7639