Diagnosis|Page 5810 > < Diagnosis|Page 5808
Page 3
background image

3. Install the torque converter with the installed leak check tool into the arbor press. Secure the press. Apply enough force from the press to seal tool

into the torque converter.

WARNING:  ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING PRESS. 

4. Apply air pressure to valve on leak check tool.

NOTE:  Use clean dry shop air.

5. With air pressure applied to valve, inspect for leaks at converter hub, seams and studs. A soap bubble solution may be applied around those areas

to aid in diagnosis. If leaks are present, replace converter.

Diagnosis|Page 5810 > < Diagnosis|Page 5808