Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Remove the powertrain control module (PCM).
3. Remove the battery and battery tray.
4. Remove the PCM bracket.

1

Remove the 3 PCM bracket bolts.

2

Remove the PCM bracket.
-

To install, tighten to 10 Nm (89 lb-in).

5. Remove the suction accumulator outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

6. Disconnect the suction accumulator inlet fitting.