with the specified brake fluid. Never reuse the brake fluid that has been drained from the hydraulic system.

NOTE:  When any part of the hydraulic system has been disconnected for repair or new installation, air may get into the system and cause spongy
brake pedal action. This requires bleeding of the hydraulic system after it has been correctly connected. The hydraulic system can be gravity bled,
manually bled or bled with pressure bleeding equipment.

1. NOTE:  When a new brake master cylinder has been installed or the system has been emptied or partially emptied, it should be primed to prevent

air from getting into the system.

Disconnect the brake master cylinder outlet tubes.

2. NOTE:  Original equipment lines are not intended to be used during this procedure.

Install short brake tubes with the ends submerged into the brake master cylinder reservoir and fill the brake master cylinder reservoir with brake
fluid.

3. Have an assistant pump the brake pedal until clear fluid flows from both brake tubes, without air bubbles.
4. Remove the short brake tubes and install the brake outlet tubes.
5. Bleed each brake tube at the brake master cylinder as follows:

1. Have an assistant pump the brake pedal and then hold firm pressure on the brake pedal.
2. Loosen the rear brake tube fittings until a stream of brake fluid comes out. Have an assistant maintain pressure on the brake pedal while

tightening the brake tube fitting.

3. Repeat this operation until clear, bubble-free fluid comes out.
4. Refill the brake master cylinder reservoir as necessary. Repeat the bleeding operation for the front brake tube.

6. While the assistant maintains pressure on the brake pedal, tighten the brake tube fittings.

^

Tighten to 17 Nm (13 ft. lbs.).

Gravity Bleeding

WARNING:  Use of any other than approved DOT 3 motor vehicle brake fluid will cause permanent damage to brake components and will
render the brakes inoperative. Failure to follow these instructions may result in personal injury.

WARNING:  Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with eyes. Wash hands thoroughly after handling. If
brake fluid contacts eyes, flush eyes with running water for 15 minutes. Get medical attention if irritation persists. If taken internally, drink
water and induce vomiting. Get medical attention immediately. Failure to follow these instructions may result in personal injury.

CAUTION:  Brake fluid is harmful to painted and plastic surfaces. If brake fluid is spilled onto a painted or plastic surface, immediately wash it with
water.

CAUTION:  Do not allow the brake master cylinder reservoir to run dry during the bleeding operation. Keep the brake master cylinder reservoir filled