ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Keyless Entry - Keypad Inoperative|Page 9812 > < General Procedures|Page 9803
Page 1
background image

Keyless Entry Module: Customer Interest
Keyless Entry - Keypad Inoperative

TSB 05-5-5

03/21/05

KEYLESS ENTRY KEYPAD INOPERATIVE

FORD:
2004-2005 F-150

ISSUE
Some 2004-2005 F-150 vehicles built through 2/7/2005, may exhibit an inoperative keyless entry keypad. This may be due to the vehicle security
module (VSM) not being configured to accept keyless entry keypad input.

ACTION
Reprogram the VSM using the As Built Data in this TSB. Refer to the following Service Procedure to access and re-configure the VSM using WDS,
NGS+ or NGS Classic.

SERVICE PROCEDURE

WDS PROCEDURE

1.

Close any existing sessions on WDS.

2.

Disable the VSM by removing fuse F2.107, or by disconnecting VSM connector.

3.

Start a new WDS session, (select 16 Pin > all except those below, etc.).

4.

Allow WDS to identify the vehicle, perform VIN confirmation and RO screens by pressing check mark button, (VSM will fail network test
because it is disabled).

5.

Select Toolbox tab, pick Module Programming, Programmable Module Installation > VSM.

6.

Follow WDS prompts to cycle the key OFF, press check mark button.

7.

When "INSTALL A NEW MODULE IN VEHICLE" appears, reconnect VSM module or reinstall fuse F2.107.

8.

Follow prompt to cycle key ON, press check mark.

9.

When the explanation screen indicates As Built data will need to be entered, press check mark.

10.

Enter the appropriate As Built data when prompted. After entering C1-01 data from As built press the check mark. WDS will then prompt for
C1-02 data, enter 6010 0000 0033 for Regular and Super Cab, or enter 2010 0000 00F3 for SuperCrew, then press the check mark. After entering
the C1-03 data from As built press the check mark. At this point, WDS should indicate whether the programming was successful. If unsuccessful
verify good connection at DLC, good power and ground to VSM, self-test VSM, re-boot WDS and reattempt the procedure.

NGS CLASSIC OR NGS+ PROCEDURE

NOTE

NGS CLASSIC USERS START AT STEP 2 WITH LATEST LEVEL GREEN SERVICE CARD. NGS+ USERS START AT STEP 1.

1.

Select Diagnostic Data Link, VSM, Module Configuration Programming.

2.

Select Programmable Module Installation.

3.

Select VSM if prompted to select a module.

4.

Select Retrieve Backup Data.

5.

Enter "4253" for Security Code Number.

6.

Enter VIN if prompted.

7.

Enter Vehicle Data (As Built data can be obtained at the professional technician society (PTS) website).

Keyless Entry - Keypad Inoperative|Page 9812 > < General Procedures|Page 9803