4.6L (3V) engine

10. Position the EVAP purge valve into place and install the bracket bolt.

-

Tighten to 10 Nm (89 lb-in).

All engines

11. NOTE: It may take more than one key cycle to pressurize the fuel system.

Cycle the ignition key to the ON position and wait 3 seconds to pressurize the fuel system. Check for leaks before starting the engine.