ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Bag Control Module|Locations|Page 7196 > < Air Bag Control Module|Locations|Page 7194
Page 2
background image

5. Disconnect the RCM small electrical connector.
6. Remove the RCM bolts.
7. Remove the RCM.

Installation

1. Position the RCM and install the bolts.

-

Tighten to 12 Nm (9 lb-ft).

2. Make sure the connector position assurance lever is in the full RELEASE position before attempting to connect the connector.

3. CAUTION:  Putting the large restraints control module (RCM) electrical connector into the RCM on an angle can cause bad electrical

connections and damage components.

NOTE:  The RCM has been removed for clarity.

Position the large RCM electrical connector into the RCM.

-

CAUTION:  Do not push the connector on to where the lever pivots and seats itself. Light pressure is needed to get the connector into
position on the restraints control module (RCM) before using the lever to fully seat the connector.

With the large RCM electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and a slight
resistance is felt.

Air Bag Control Module|Locations|Page 7196 > < Air Bag Control Module|Locations|Page 7194