Torque Converter: Testing and Inspection
Torque Converter

Torque Converter 

1. A new or remanufactured torque converter must be installed if one or more of the following statements is true:

^

A torque converter malfunction has been determined based on complete diagnostic procedures.

^

Converter stud or studs, impeller hub or bushing are damaged.

^

Discoloration (due to overheating).

^

Evidence of transmission assembly or transmission fluid contamination due to the following transmission or converter failure modes:
-

Major metallic failure.

-

Multiple clutches or clutch plate failures.

-

Sufficient component wear which results in metallic contamination.

-

Internal torque converter contamination present. For additional information, refer to Torque Converter Contamination Inspection.