vacuum pump, charging meter and manifold gauge set.

-

Leaks in refrigerant system service equipment, hoses or gauges can cause a leak that may be misinterpreted as a problem with the vehicle's
refrigerant system. It is necessary to leak-test all refrigerant system service equipment, hoses and gauges on a weekly basis to verify that no leaks
are present.

1. Lubricate the refrigerant system with the correct amount of clean PAG oil.
2. Assemble the R-134a manifold gauge set, automatic refrigerant charging meter and R-134a supply tank following the automatic refrigerant

charging meter operating instructions.

3. Charge the refrigerant system following the automatic refrigerant charging meter operating instructions.
4. If the refrigerant flow stops before the refrigerant charge is complete, start the engine, select A/C operation and allow the refrigerant charge to

complete.