2. Remove the RH instrument panel brace.

1. Remove the lower nut.
2. Remove the upper bolt.
3. Remove the brace.

3. Remove the LH instrument panel lower nut and position brace out of the way.

4. Remove the floor duct.

1. Remove the two screws (one each side).
2. Remove the floor duct.

5. Remove the panel/floor door vacuum control motor.

1. Disconnect the vacuum line connector.
2. Remove the two panel/floor door vacuum control motor screws.
3. Slide the rod out of the door and remove the panel/floor door vacuum control motor.