Refrigerant Oil: Capacity Specifications

Refrigerant Oil Addition 

During A/C Compressor Replacement 
A new FS-10 service replacement A/C compressor contains no refrigerant oil.

1. If the amount of oil drained from the removed A/C compressor is between 85 and 142 ml (3 oz. to 5 oz.), pour the same amount plus 1 (one)

ounce of clean oil into the new A/C compressor.

2. If the amount of oil drained from the old A/C compressor is greater than 142 ml (5 oz.), pour only 142 ml (5 oz.) of clean refrigerant oil into

the new A/C compressor.

3. If the amount of refrigerant oil drained from the old A/C compressor is less than 85 ml (3 oz.), pour 85 ml (3 oz.) of clean refrigerant oil into

the new compressor.

During Component Replacement 
When replacing components of the air conditioning refrigerant system, add oil to the replacement components.